UCL logo

UCL Discovery

UCL home » Library Services » Electronic resources » UCL Discovery

Browse by UCL Departments and Centres

Up a level
Export as [feed] RSS 2.0 [feed] RSS 1.0 [feed] Atom
Group by: Author | Type
Jump to: A | B | C | D | E | F | G | H | J | M | N | P | S | T | V | W
Number of items: 69.

A

ARRIDGE, SR; SCHWEIGER, M; HIRAOKA, M; DELPY, DT; (1993) A FINITE-ELEMENT APPROACH FOR MODELING PHOTON TRANSPORT IN TISSUE. MED PHYS , 20 (2) 299 - 309.

ARRIDGE, SR; SCHWEIGER, M; HIRAOKA, M; DELPY, DT; (1993) PERFORMANCE OF AN ITERATIVE RECONSTRUCTION ALGORITHM FOR NEAR-INFRARED ABSORPTION AND SCATTER IMAGING. PROCEEDINGS OF PHOTON MIGRATION AND IMAGING IN RANDOM MEDIA AND TISSUES , 1888 360 - 371.

B

Beard, PC; Cornforth, RJ; Essenpreis, M; Mills, TN; (1993) Photoacoustic response of post mortem human aorta to 10ns laser pulses. In: (Proceedings) Lasers in Medicine - Proceedings of the 11th International Congress, Munich,. (pp. 148 - 151).

Boone, K; Lewis, A; Holder, DS; (1993) Electrical impedance tomography (EIT) imaging of cortical spreading depression in the anaesthetized rabbit. Journal of Physiology , 473

C

Cady, EB; Boesch, C; Martin, E; (1993) Magnetic resonance spectroscopy. In: Haddad, J and Saliba, E, (eds.) Perinatal Asphyxia. (166 - 194). Springer: Heidelberg.

Cady, EB; Lorek, A; Penrice, J; Edwards, AD; Brown, G; Owen-Reece, H; ... Reynolds, EOR; + view all (1993) Proton metabolite spin-spin relaxation and ATP control of the Na+/K+ pump during and after acute cerebral hypoxia-ischaemia in the newborn piglet. In: (Proceedings) European Society for Magnetic Resonance in Neuropediatrics 3rd Biennial Meeting, Brussels, Belgium..

Cady, EB; Roth, S; Lorek, A; Wylezinska, M; Aldridge, RF; (1993) A probehead for combined imaging, 1H PRESS, and 31P ISIS absolute quantitation of the brains of newborn human infants. In: Proceedings Society for Magnetic Resonance in Medicine, 12th Annual Meeting. (pp. 1330 - 1330).

Cady, EB; Wyatt, JS; Lorek, A; Penrice, J; Roth, S; Aldridge, RF; ... Reynolds, EOR; + view all (1993) 1H magnetic resonance spectroscopy studies of the brains of newborn infants following perinatal hypoxia-ischaemia. In: (Proceedings) British Institute of Radiology "Progress in In Vivo Magnetic Resonance", London, UK..

Cady, EB; Wyatt, JS; Lorek, A; Penrice, J; Roth, S; Aldridge, RF; ... Reynolds, EOR; + view all (1993) Studies by localised 1H magnetic resonance spectroscopy of the brains of normal newborn infants and following perinatal hypoxia-ischaemia. In: (Proceedings) European Society for Magnetic Resonance in Neuropediatrics 3rd Biennial Meeting, Brussels, Belgium..

Cady, EB; Wyatt, JS; Lorek, A; Takei, Y; Penrice, J; Edwards, AD; ... Reynolds, EOR; + view all (1993) Delayed cerebral energy failure following recovery from acute hypoxia-ischaemia in the newborn piglet: 31P and 1H magnetic resonance spectroscopy studies. In: (Proceedings) European Society for Magnetic Resonance in Neuropediatrics 3rd Biennial Meeting, Brussels, Belgium..

Cady, EB; Wyatt, JS; Takei, Y; Lorek, A; Cooper, C; Edwards, AD; ... Reynolds, EOR; + view all (1993) Cerebral energy failure secondary to acute hypoxia-ischaemia in the newborn pig studied by 1H magnetic resonance spectroscopy. In: Proceedings Society for Magnetic Resonance Medicine, 12th Annual Meeting. (pp. 1502 - 1502).

Cady, EB; Wyatt, JS; Takei, Y; Lorek, A; Edwards, AD; Roth, S; ... Reynolds, EOR; + view all (1993) 31P magnetic resonance spectroscopy studies of cerebral energy failure secondary to acute hypoxia-ischaemia in the newborn pig. In: Proceedings Society for Magnetic Resonance in Medicine, 12th Annual Meeting. (pp. 1493 - 1493).

Cady, EB; Wyatt, JS; Takei, Y; Lorek, A; Penrice, J; Edwards, AD; ... Reynolds, EOR; + view all (1993) Cerebral energy failure secondary to acute hypoxia-ischaemia: Continuous 7 tesla 31P and 1H magnetic resonance spectroscopy studies over 48 hours. In: (Proceedings) British Institute of Radiology "Progress in In Vivo Magnetic Resonance", London, UK..

Cottenden, A; Ledger, D; (1993) Incontinence pads: predicting their leakage performance using laboratory tests. Neurourol Urodyn , 12 (3) 289 - 291.

COTTENDEN, AM; LEDGER, DJ; (1993) PREDICTING THE LEAKAGE PERFORMANCE OF BODYWORN DISPOSABLE INCONTINENCE PADS USING LABORATORY TESTS. JOURNAL OF BIOMEDICAL ENGINEERING , 15 (3) 212 - 220.

D

De Blasi, RA; Cope, M; Elwell, C; Safoue, F; Ferrari, M; (1993) Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy. Eur J Appl Physiol Occup Physiol , 67 (1) 20 - 25.

Duncan, A; Whitlock, TL; Cope, M; Delpy, DT; (1993) Multiwavelength, wideband, intensity-modulated optical spectrometer for near-infrared spectroscopy and imaging. Proceedings of SPIE , 1888 248 - 257.

E

Edwards, A; Richardson, C; van, DZP; Elwell, C; Wyatt, J; (1993) Measurement of haemoglobin flow using near infrared spectroscopy (NIRS). Journal of Applied Physiology , 75 (4) 1884 - 1889.

ELWELL, CE; OWENREECE, H; COPE, M; WYATT, JS; EDWARDS, AD; DELPY, DT; REYNOLDS, EOR; (1993) MEASUREMENT OF ADULT CEREBRAL HEMODYNAMICS USING NEAR-INFRARED SPECTROSCOPY. ACTA NEUROCHIR 74 - 80.

ESSENPREIS, M; COPE, M; ELWELL, CE; ARRIDGE, SR; VANDERZEE, P; DELPY, DT; (1993) WAVELENGTH DEPENDENCE OF THE DIFFERENTIAL PATHLENGTH FACTOR AND THE LOG SLOPE IN TIME-RESOLVED TISSUE SPECTROSCOPY. In: Dirnagl, U and Villringer, A and Einhaupl, KM, (eds.) OPTICAL IMAGING OF BRAIN FUNCTION AND METABOLISM. (pp. 9 - 20). PLENUM PRESS DIV PLENUM PUBLISHING CORP

Essenpreis, M; Elwell, C; Arridge, S; van, DZP; Delpy, D; (1993) Spectral dependence of temporal point spread functions in human tissue. Applied Optics , 32 (4) 418 - 425.

ESSENPREIS, M; ELWELL, CE; COPE, M; VANDERZEE, P; ARRIDGE, SR; DELPY, DT; (1993) SPECTRAL DEPENDENCE OF TEMPORAL POINT SPREAD FUNCTIONS IN HUMAN TISSUES. APPL OPTICS , 32 (4) 418 - 425.

F

Firbank, M; Hiraoka, M; Delpy, DT; (1993) Development of a stable and reproducible tissue-equivalent phantom for use in infrared spectroscopy and imaging. Proceedings of SPIE , 1888 264 - 270.

G

Galgut, PN; Todd-Pokropek, A; (1993) Recurrence of destructive periodontal disease after treatment. A long term study. Bulletin of the Group of International Research Scientists in Stomatology and Odontology , 36 (1) 15 - 21.

H

HEBDEN, JC; (1993) LINE SCAN ACQUISITION FOR TIME-RESOLVED IMAGING THROUGH SCATTERING MEDIA. OPT ENG , 32 (3) 626 - 633.

HEBDEN, JC; (1993) TIME-RESOLVED IMAGING OF OPAQUE AND TRANSPARENT SPHERES EMBEDDED IN A HIGHLY SCATTERING MEDIUM. APPL OPTICS , 32 (21) 3837 - 3841.

HEBDEN, JC; (1993) TIME-RESOLVED IMAGE-CONTRAST OF SPHERES EMBEDDED IN HIGHLY SCATTERING MEDIA. In: Chance, B and Alfano, RR and Katzir, A, (eds.) PROCEEDINGS OF PHOTON MIGRATION AND IMAGING IN RANDOM MEDIA AND TISSUES. (pp. 22 - 27). SPIE - INT SOC OPTICAL ENGINEERING

HEBDEN, JC; WONG, KS; (1993) TIME-RESOLVED OPTICAL TOMOGRAPHY. APPL OPTICS , 32 (4) 372 - 380.

HELPERN, JA; DERESKI, MO; KNIGHT, RA; ORDIDGE, RJ; CHOPP, M; QING, ZX; (1993) HISTOPATHOLOGICAL CORRELATIONS OF NUCLEAR-MAGNETIC-RESONANCE IMAGING PARAMETERS IN EXPERIMENTAL CEREBRAL-ISCHEMIA. MAGN RESON IMAGING , 11 (2) 241 - 246.

HELPERN, JA; VANDELINDE, AMQ; WELCH, KMA; LEVINE, SR; SCHULTZ, LR; ORDIDGE, RJ; ... HUGG, JW; + view all (1993) ACUTE ELEVATION AND RECOVERY OF INTRACELLULAR [MG2+] FOLLOWING HUMAN FOCAL CEREBRAL-ISCHEMIA. NEUROLOGY , 43 (8) 1577 - 1581.

Hill, DL; Hawkes, DJ; Hussain, Z; Green, SE; Ruff, CF; Robinson, GP; (1993) Accurate combination of CT and MR data of the head: validation and applications in surgical and therapy planning. Comput Med Imaging Graph , 17 (4-5) 357 - 363.

HIRAOKA, M; FIRBANK, M; ESSENPREIS, M; COPE, M; ARRIDGE, SR; VANDERZEE, P; DELPY, DT; (1993) A MONTE-CARLO INVESTIGATION OF OPTICAL PATHLENGTH IN INHOMOGENEOUS TISSUE AND ITS APPLICATION TO NEAR-INFRARED SPECTROSCOPY. PHYS MED BIOL , 38 (12) 1859 - 1876.

HIRAOKA, M; FIRBANK, M; ESSENPREIS, M; COPE, M; ARRIDGE, SR; VANDERZEE, P; DELPY, DT; (1993) MONTE-CARLO SIMULATION OF LIGHT TRANSPORT THROUGH INHOMOGENEOUS TISSUE. PROCEEDINGS OF PHOTON MIGRATION AND IMAGING IN RANDOM MEDIA AND TISSUES , 1888 149 - 159.

Holder, D; (1993) Clinical and physiological applications of electrical impedance tomography. CRC Press

Holder, DS; (1993) EIT and scalp electrodes. Clinical and Physiological Applications of Electrical Impedance Tomography 185 - ?.

Holder, DS; (1993) Localization of functional activity in the brain by electrical impedance tomography (EIT). Electroencephalography and Clinical Neurophysiology , 87 (2) S60 - ?.

Holder, DS; (1993) Opportunities for EIT in the nervous system. Clinical and Physiological Applications of Electrical Impedance Tomography 166 - 175.

Holder, DS; (1993) Physiological constraints to imaging brain function using scalp electrodes. Clinical and Physiological Applications of Electrical Impedance Tomography. D. Holder (ed). UCL Press, London 185 - 200.

Holder, DS; Binnie, CD; Polkey, CE; (1993) Cerebral impedance changes during seizures in human subjects: implications for non-invasive focus detection by electrical impedance tomography (EIT). Brain Topography , 5 331 - ?.

Holder, DS; Brown, BH; (1993) Biomedical applications of EIT: a critical review. Clinical and physiological applications of electrical impedance tomography 6 - 40.

Holder, DS; Temple, AJ; (1993) Effectiveness of the Sheffield EIT system in distinguishing patients with pulmonary pathology from a series of normal subjects. Clinical and physiological applications of electrical impedance tomography 277 - 298.

Holder, DS; Temple, AJ; (1993) Effectiveness of the Sheffield KIT system in. Clinical and Physiological Applications of Electrical Impedance Tomography 277 - ?.

J

JIANG, Q; ZHANG, ZG; CHOPP, M; HELPERN, JA; ORDIDGE, RJ; GARCIA, JH; ... KNIGHT, RA; + view all (1993) TEMPORAL EVOLUTION AND SPATIAL-DISTRIBUTION OF THE DIFFUSION CONSTANT OF WATER IN RAT-BRAIN AFTER TRANSIENT MIDDLE CEREBRAL-ARTERY OCCLUSION. J NEUROL SCI , 120 (2) 123 - 130.

M

Martinez-Davalos, A; SPELLER, R; Miller, DJ; Shekhtman, LI; Baru, SE; Khabakhpashev, AG; Ponomorev, OA; (1993) A low-dose digital x-ray system with improved spatial resolution: preliminary evaluation. Publications of the European Organisation for Nuclear Research

Martinez-Davalos, A; Speller, RD; (1993) A preliminary evaluation of a CCD-based digital x-ray system. Physica Medica , 9 (2-3) 209 - 213.

MARTINEZDAVALOS, A; SPELLER, RD; HORROCKS, JA; MILLER, DJ; BARU, SE; KHABAKHPASHEV, AG; ... SHEKHTMAN, LI; + view all (1993) EVALUATION OF A NEW LOW-DOSE DIGITAL X-RAY SYSTEM. PHYS MED BIOL , 38 (10) 1419 - 1432.

Matcher, SJ; Cope, M; Delpy, DT; (1993) Quantification of tissue chromophore concentration via water-peak measurements in near-infrared spectroscopy. Proceedings of SPIE , 1888 239 - 247.

N

NEELIN, P; CROSSMAN, J; HAWKES, D; MA, Y; EVANS, A; (1993) VALIDATION OF AN MRI/PET LANDMARK REGISTRATION METHOD USING 3D SIMULATED PET IMAGES AND POINT SIMULATIONS. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS , 17 (4-5) 351 - 356. 10.1016/0895-6111(93)90028-L.

Neelin, P; Crossman, J; Hawkes, DJ; Ma, Y; Evans, AC; (1993) Validation of an MRI/PET landmark registration method using 3D simulated PET images and point simulations. COMPUT MED IMAGING GRAPH , 17 (895-6111 (Print), 4-5) 351 - 356.

Newell, JC; Isaacson, D; Cheney, M; Saulnier, GJ; Gisser, DG; Goble, JC; ... Holder, DS; + view all (1993) In vivo impedance images using sinusoidal current patterns. Clinical and Physiological Applications of Electrical Impedance Tomography 277 - 298.

Norris, C; Cottenden, A; Ledger, D; (1993) Underpad overview. Nurs Times , 89 (21) 68 - passim.

P

Philp, EJ; Cottenden, AM; (1993) Picking and choosing. Nursing Times , 89 (30) 70 - 83.

Philp, EJ; Cottenden, AM; Ledger, DJ; (1993) A testing time. Nursing Times , 89 (4) 59 - 62.

Philp, EJ; Cottenden, AM; Ledger, DJ; (1993) Mix and match. Nursing Times , 89 (16) 70 - 74.

Philp, EJC; A M, L; D, J; (1993) Well disposed? Nursing Times , 89 (16) 65 - 68.

Philp, J; Cottenden, A; (1993) Continence consumer test. Elder Care , 5 (5) 27 - 30.

Philp, J; Cottenden, A; Ledger, D; (1993) Continence. A testing time. Nurs Times , 89 (4) 59 - 62.

Philp, J; Cottenden, A; Ledger, D; (1993) Continence. Mix and match. Nurs Times , 89 (16) 70 - 74.

Philp, J; Cottenden, A; Ledger, D; (1993) Continence. Well disposed? Nurs Times , 89 (16) 65 - 68.

Philp, J; Cottenden, A; Ledger, D; (1993) Wash and wear. Nurs Times , 89 (21) 63 - 66.

S

Schweiger, M; Arridge, SR; Delpy, DT; (1993) Application of the finite-element method for the forward and inverse models in optical tomography. Journal of Mathematical Imaging and Vision , 3 , Article 3. 10.1007/BF01248356.

Schweiger, M; Arridge, SR; Hiraoka, M; Firbank, M; Delpy, DT; (1993) Comparison of a finite-element forward model with experimental phantom results: application to image reconstruction. Proceedings of SPIE , 1888 179 - 190.

Smallwood, RH; Nour, S; Mangnall, YF; Smythe, A; Holder, DS; (1993) Impedance imaging and gastric motility. Clinical and Physiological Applications of Electrical Impedance Tomography 145 - 153.

SPELLER, R; Baba-Hamed, T; (1993) Dual energy probe for tissue characterisation. Physics in medicine and biology , 38 379 - 388.

T

Takei, Y; Edwards, AD; Lorek, A; Peebles, DM; Belai, A; Cope, M; ... Reynolds, EO; + view all (1993) Effects of N-omega-nitro-L-arginine methyl ester on the cerebral circulation of newborn piglets quantified in vivo by near-infrared spectroscopy. Pediatric Research , 34 354 - 359.

Thornburn, P; Cottenden, A; Ledger, D; (1993) Mind the quality. Care Weekly (Apr 15) 14 - 14.

V

van der Zee, P; Essenpreis, M; Delpy, DT; (1993) Optical properties of brain tissue. Proceedings of SPIE , 1888 454 - 465.

W

Wylezinska, M; Cady, EB; (1993) Quality assurance in 31P ISIS absolute quantitation. In: Proceedings Society for Magnetic Resonance in Medicine, 12th Annual Meeting. (pp. 971 - 971).

This list was generated on Sun Dec 14 06:45:36 2014 GMT.