UCL logo

UCL Discovery

UCL home » Library Services » Electronic resources » UCL Discovery

Browse by UCL Departments and Centres

Up a level
Export as [feed] RSS 2.0 [feed] RSS 1.0 [feed] Atom
Group by: Author | Type
Jump to: A | B | C | D | E | F | G | H | I | J | K | L | M | O | P | R | S | T | W | Y | Z
Number of items: 162.

A

Amess, PN and Penrice, J and Cady, EB and Lorek, A and Wylezinska, M and Cooper, CE and DSouza, P and Tyszczuk, L and Thoresen, M and Edwards, AD and Wyatt, JS and Reynolds, EOR (1997) Mild hypothermia after severe transient hypoxia-ischemia reduces the delayed rise in cerebral lactate in the newborn piglet. PEDIATR RES , 41 (6) 803 - 808.

Arfelli, F and Barbiellini, G and Bonvicini, V and Bravin, A and Burger, P and Cantatore, G and Castelli, E and Di Michiel, M and Longo, R and Olivo, A and Pani, S and Pontoni, D and Poropat, P and Prest, M and Rashevsky, A and Tromba, G and Vacchi, A and Zampa, N (1997) Design and evaluation of AC-coupled, FOXFET-biased, "edge-on" silicon strip detectors for X-ray imaging. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT , 385 (2) 311 - 320.

Arfelli, F and Barbiellini, G and Bonvicini, V and Bravin, A and Cantatore, G and Castelli, E and Castelli, E and Dalla Palma, L and Di Michiel, M and Longo, R and Olivo, A and Pani, S and Pontoni, D and Poropat, P and Prest, M and Rashevsky, A and Tromba, G and Vacchi, A (1997) The digital mammography program at the SR light source in Trieste. EEE TRANSACTIONS ON NUCLEAR SCIENCE , 44 (6) 2395 - 2399.

Arfelli, F and Barbiellini, G and Bonvicini, V and Bravin, A and Cantatore, G and Castelli, E and Cristaudo, P and Di Michiel, M and Longo, R and Olivo, A and Pani, S and Pontoni, D and Poropat, P and Prest, M and Rashevsky, A and Tomasini, F and Tromba, G and Vacchi, A (1997) SYRMEP: an innovative detection system for soft X-rays. In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. (pp. 188 - 191). ELSEVIER SCIENCE BV: AMSTERDAM, NETHERLANDS.

Arfelli, F and Barbiellini, G and Bonvicini, V and Bravin, A and Cantatore, G and Castelli, E and Cristaudo, P and Di Michiel, M and Longo, R and Olivo, A and Pani, S and Pontoni, D and Poropat, P and Prest, M and Rashevsky, A and Tromba, G and Vacchi, A (1997) A digital readout system for the SYRMEP silicon strip detectors. In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. (pp. 392 - 395). ELSEVIER SCIENCE BV: AMSTERDAM, NETHERLANDS.

Arfelli, F and Barbiellini, G and Bonvicini, V and Bravin, A and Cantatore, G and Castelli, E and Dalla Palma, L and Di Michiel, M and Longo, R and Olivo, A and Pani, S and Pontoni, D and Poropat, P and Prest, M and Richter, G and Rosei, R and Sessa, M and Tromba, G and Turchetta, R and Vacchi, A (1997) The Mammography Project at ELETTRA. In: PHYSICA MEDICA. (pp. 7 - 12). GIARDINI EDITORI S A LUGANO: LUGANO, SWITZERLAND.

Arfelli, F and Barbiellini, G and Bonvicini, V and Bravin, A and Cantatore, G and Castelli, E and Di Michiel, M and Longo, R and Olivo, A and Pani, S and Pontoni, D and Poropat, P and Prest, M and Rashevsky, A and Tromba, G and Vacchi, A and Zampa, N (1997) An ''edge-on'' silicon strip detector for X-ray imaging. IEEE TRANSACTIONS ON NUCLEAR SCIENCE , 44 (3) 874 - 880.

Arfelli, F and Bonvicini, V and Bravin, A and Cantatore, G and Castelli, E and Dalla Palma, L and Di Michiel, M and Longo, R and Olivo, A and Pani, S and Pontoni, D and Poropat, P and Prest, M and Rashevsky, A and Tromba, G and Vacchi, A (1997) A linear array silicon pixel detector: images of a mammographic test object and evaluation of delivered doses. PHYSICS IN MEDICINE AND BIOLOGY , 42 (8) 1565 - 1573.

Arridge, SR and Hebden, JC (1997) Optical imaging in medicine .2. Modelling and reconstruction. PHYS MED BIOL , 42 (5) 841 - 853.

Atkinson, D and Hill, DLG and Stoyle, PNR and Summers, PE and Keevil, SF (1997) Automatic Correction of Motion Artifacts in Magnetic Resonance Images Using an Entropy Focus Criterion. IEEE Trans. Med. Imaging , 16 , Article 6. 10.1109/42.650886.

B

Barratt, DC and Humphries, KH and Fredfeldt, KE and Greenhalgh, RM and Davies, AH (1997) A new phantom for three-dimensional ultrasound volume measurement. In: European Journal of Ultrasound. (pp. 7 - 8).

Beard, PC and Mills, TN (1997) Characterization of post mortem arterial tissue using time-resolved photoacoustic spectroscopy at 436, 461 and 532 nm. Physics in Medicine and Biology , 42 (1) 177 - 198.

Beard, PC and Mills, TN (1997) Characterization of post mortem arterial tissue using time-resolved photoacoustic spectroscopy at 436, 461 and 532 nm. PHYS MED BIOL , 42 (1) 177 - 198.

Beard, PC and Mills, TN (1997) Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer. Electronics Letters , 33 (9) 801 - 803.

Beard, PC and Mills, TN (1997) Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer. ELECTRON LETT , 33 (9) 801 - 803.

Binzoni, T and Cerretelli, P and Ferrari, M and Delpy, DT (1997) Metabolic studies of human skeletal muscle by near infrared spetroscopy: possible applications in space research. International Journal of Sports Medicine (18) 312 - 314.

Blumberg, RM and Cady, EB and Wigglesworth, JS and McKenzie, JE and Edwards, AD (1997) Relation between delayed impairment of cerebral energy metabolism and infarction following transient focal hypoxia-ischaemia in the developing brain. Experimental Brain Research , 113 (1) 130 - 137.

Bugbee, M and Donaldson, N and Taylor, JT (1997) Design of an implantable selective nerve stimulator. In: Design of an implantable selective nerve stimulator.

Bugbee, MB and Donaldson, N and Taylor, JT (1997) Design of a Selective Nerve Stimulator. In: (Proceedings) International FES Society Conference, Vancouver.

Bull, CR and Zwiggelaar, R and Speller, RD (1997) Review of inspection techniques based on the elastic and inelastic scattering of X-rays and their potential in the food and agricultural industry. J FOOD ENG , 33 (1-2) 167 - 179.

C

Cady, EB (1997) Improved analysis of phosphorus spin-echo spectra using phase-modulated and proton-coupled analytical functions. In: Proceedings International Society for Magnetic Resonance in Medicine 5th Annual Meeting. (pp. 1418 - 1418).

Cady, EB (1997) In-vivo metabolite quantification: motivations, methods, and problems. In: (Proceedings) French Chemistry Society, Groupe D'Etude Resonance Magnetique (GERM) 15th Annual Congress, St Pierre d'Oleron, France..

Cady, EB (1997) Magnetic resonance spectroscopy studies of experimental perinatal asphyxia. In: Neuropediatrics. (pp. 346 - ?).

Cady, EB (1997) Phosphorus and proton magnetic resonance spectroscopy of the brains of newborn human infants. In: Bachelard, H, (ed.) Magnetic Resonance Spectroscopy and Imaging in Neurochemistry. (289 - 327). Plenum Press,: New York.

Cady, EB and Amess, P and Penrice, J and Wylezinska, M and Sams, V and Wyatt, JS (1997) Early cerebral-metabolite quantification in perinatal hypoxic-ischaemic encephalopathy by proton and phosphorus magnetic resonance spectroscopy. MAGN RESON IMAGING , 15 (5) 605 - 611.

Cady, EB and D'Souza, PC (1997) Analysis of proton brain spectra from human infants by fitting linear combinations of model spectra. Journal of Magnetic Resonance Analysis , 3 (1) 5 - 14.

Cady, EB and D'Souza, PC (1997) Improved estimation of regional absolute cerebral temperature by 1H magnetic resonance spectroscopy. In: Proceedings International Society for Magnetic Resonance in Medicine 5th Annual Meeting, 12-18 April, Vancouver, Canada. (pp. 1433 - 1433).

Calamante, F and Lythgoe, MF and Pell, GS and Thomas, DL and Busza, AL and Gadian, DG and Ordidge, RJ (1997) Comparison of early T1, T2, perfusion, diffusion, and MTC changes during focal cerebral ischaemia in the rat at 8.5 T. In: Proceedings of the Annual Meeting of the International Society of Magnetic Resonance in Medicine. (pp. 600 - ?).

Cameron, J and Bayford, RH and Binnie, CD and Holder, DS (1997) Software for transmission and remote viewing of digitalEEG data across the telephone network. MED BIOL ENGIN COMPUT , 35(Sup

Chance, B and Cooper, C and Delpy, DT and Reynolds, EOR (1997) Near infrared spectroscopy and imaging of living systems. Philosophical Transactions of the Royal Society B: Biological Sciences , 352 643 - 761.

Clemence, M and Springett, R and Amess, PN and Penrice, J and Thornton, JS and Punwani, S and Wyatt, JS and Ordidge, RJ and Cady, EB (1997) Near infra-red spectroscopy shows path length changes which correlate with T2 in a piglet model of cerebral hypoxia-ischaemia. In: MAGMA. (pp. 64 - 65).

Cooper, C and Cope, M and Quaresima, V and Ferrari, M and Nemoto, E and Springett, R and Matcher, SJ and Amess, PN and Penrice, J and Tyszczuk, L and Wyatt, JS and Delpy, DT (1997) Measurement of cytochrome oxidase redox state by near infrared spectroscopy. Advances in Experimental Medicine and Biology (413) 63 - 73.

Cooper, C and Delpy, DT (1997) Introduction. Philosophical Transactions of the Royal Society of London Series B-Biological Sciences. Philosophical Transactions of the Royal Society B: Biological Sciences (352 (1) 647 - 648.

Cooper, C and Sharpe, M and Elwell, CE and Springett, R and Penrice, J and Tyszczuk, L and Amess, PN and Wyatt, JS and Quaresima, V and Delpy, DT (1997) The cytochrome oxidase redox state in vivo. In: Advances in Experimental Medicine and Biology. (pp. 449 - 456).

Cooper, C and Sharpe, M and Elwell, CE and Springett, R and Penrice, J and Tyszczuk, L and Amess, PN and Wyatt, JS and Quaresima, V and Delpy, DT (1997) The cytochrome oxidase redox state in vivo. Advances in Experimental Medicine and Biology (428) 449 - 456.

Cottenden, AM (1997) Male incontinence device.

Cottenden, AM (1997) Male incontinence device.

Cottenden, AM and Dean, GE and Brooks, RJ (1997) Predicting the leakage performance of small bodyworn disposable incontinence pads using laboratory tests. MEDICAL ENGINEERING & PHYSICS , 19 (6) 556 - 571.

Court, D and Bayford, RH and Holder, DS (1997) Stainless steel and Silicone rubber Bio-electrodes forexternal and in vitro applications. MED BIOL ENGIN COMPUT , 35(Sup

D

D'Antona, D and Aldrich, CJ and O'Brien, P and Lawrence, S and Delpy, DT and Wyatt, JS (1997) Recent advances in fetal near infrared spectroscopy. Journal of Biomedical Optics (2 (1)) 15 - 21.

Delpy, DT and Cope, M (1997) Quantification in tissue near-infrared spectroscopy. Philosophical Transactions of the Royal Society B: Biological Sciences (352 (1) 649 - 659.

Donaldson, N and Perkins, TA and Worley, ACM (1997) Lumbar root stimulation for restoring leg funtion. Methods: Stimulator and measurement of muscle acitons. Artificial Organs (21) 247 - 249.

Donaldson, N and Rushton, D and Tromans, T (1997) Neuroprostheses for leg function after spinal-cord injury. LANCET , 350 (9079) 711 - 711.

Donaldson, N and Van der Herberg, E (1997) Apparatus to measure the determinants of posture. In: Apparatus to measure the determinants of posture.

Donaldson, ND and Perkins, TA and Worley, AC (1997) Lumbar root stimulation for restoring leg function: stimulator and measurement of muscle actions. Artificial Organs , 21 (3) 247 - 249.

Donaldson, NDN and Munih, M and Phillips, GF and Perkins, TA (1997) Apparatus and methods for studying artificial feedback-control of the plantarflexors in paraplegics without interference from the brain. MED ENG PHYS , 19 (6) 525 - 535.

Donaldson, NDN and Perkins, TA and Worley, ACM (1997) Lumbar root stimulation for restoring leg function: Stimulator and measurement of muscle actions. In: ARTIFICIAL ORGANS. (pp. 247 - 249). BLACKWELL SCIENCE INC

E

Elwell, CE and Cope, M and Delpy, DT (1997) An analytical method for determining cerebrovascular transit time using near infrared spectroscopy. Advances in Experimental Medicine and Biology (428) 561 - 568.

Elwell, CE and Cope, M and Delpy, DT (1997) An analytical method for determining cerebrovascular transit time using near infrared spectroscopy. In: Harrison, DK and Delpy, DT, (eds.) OXYGEN TRANSPORT TO TISSUE XIX. (pp. 561 - 568). PLENUM PRESS DIV PLENUM PUBLISHING CORP

Elwell, CE and Matcher, SJ and Tyszczuk, L and Meek, JH and Delpy, DT (1997) Measurement of cerebral venous saturation in adults using near infrared spectroscopy. Advances in Experimental Medicine and Biology (411) 453 - 460.

Elwell, CE and Matcher, SJ and Tyszczuk, L and Meek, JH and Delpy, DT (1997) Measurement of cerebral venous saturation in adults using near infrared spectroscopy. In: Nemoto, EM and LaManna, JC, (eds.) OXYGEN TRANSPORT TO TISSUE XVIII. (pp. 453 - 460). PLENUM PRESS DIV PLENUM PUBLISHING CORP

F

Fader, M and Pettersson, L and Brooks, R and Dean, G and Wells, M and Cottenden, A and Malone-Lee, J (1997) A multicentre comparative evaluation of catheter valves. Br J Nurs , 6 (7) 359 - 367.

Fader, M and Pettersson, L and Clinton, L and Dean, G and Brooks, R and Cottenden, AM (1997) Medical Devices Agency (UK), Disability Equipment Assessment Report, Catheter valves: a multicentre comparative evaluation. (Catheter valves: a multicentre comparative evaluation A22 , pp. 1 - 37 ). Medical Devices Agency (UK)

Fader, M and Pettersson, L and Dean, G and Brookes, R and Cottenden, A (1997) The art of discretion: an evaluation of catheter valves. Nursing Times , 93 (30) 14 - ?.

Farquharson, MJ and Luggar, RD and Speller, RD (1997) Multivariate calibration for quantitative analysis of EDXRD spectra from a bone phantom. APPL RADIAT ISOTOPES , 48 (8) 1075 - 1082.

Farquharson, MJ and Speller, RD and Brickley, M (1997) Measuring bone mineral density in archaeological bone using energy dispersive low angle X-ray scattering techniques. J ARCHAEOL SCI , 24 (8) 765 - 772.

Firbank, M and Okada, E and Delpy, DT (1997) Investigation of the effect of discrete absorbers upon the measurement of blood volume with near-infrared spectroscopy. Physics in Medicine and Biology , 42 (3) 465 - 477.

Fry, ME and Pittard, S and Summers, IR and Vennart, W and Goldie, FT (1997) A programmable eddy-current compensation system for MRI and localized spectroscopy. Journal of Magnetic Resonance Imaging , 7 (2) 455 - 458.

Fusgen, I and Bienstein, C and Bohmer, F and Busch, B and Cottenden, A and Heidler, A and Scherr, A and Pullen, R (1997) Internationale Konferenz uber Harninkontinenz im Alter-Arbeitsgruppe Interdisziplinare Zuammenarbeit in der Inkontinenzbetreuung. In: (Proceedings) Proceedings of A WHO Concensus Conference: Internationale Konferenz uber Harninkontinenz im Alter - Arbeitsgruppe Interdisziplinare Zusammenarbeit in der Inkontinenzbetreuung.

G

Gamba, H and Delpy, DT (1997) Artefacts in MR images of electrical current distribution. PHYS MED BIOL , 42 (12) 2481 - 2491.

Gandjbakhche, AH and Chernomordik, V and Bonner, RF and Hebden, JC and Nossal, R (1997) Use of time-dependent contrast functions to discriminate between the scattering and absorption properties of abnormal regions hidden within a tissue-like phantom. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF , 2979 211 - 218.

Gibson, A and Bayford, R and Holder, DS (1997) The effect of skull impedance on Electrical Impedance Tomography of the neonatal head. Medical and Biological Engineering and Computing , 35 (1) 328 - ?.

H

Hall, DJ and Hebden, JC and Delpy, DT (1997) Evaluation of spatial resolution as a function of thickness for time-resolved optical imaging of highly scattering media. MED PHYS , 24 (3) 361 - 368.

Hall, DJ and Hebden, JC and Delpy, DT (1997) Imaging very-low-contrast objects in breastlike scattering media with a time-resolved method. APPL OPTICS , 36 (28) 7270 - 7276.

Hebden, JC and Arridge, SR and Delpy, DT (1997) Optical imaging in medicine .1. Experimental techniques. PHYS MED BIOL , 42 (5) 825 - 840.

Hebden, JC and Delpy, DT (1997) Diagnostic imaging with light. BRIT J RADIOL , 70 S206 - S214.

Hebden, JC and Delpy, DT (1997) Diagnostic imaging with light. Br J Radiol , 70 Spec No S206 - S214.

Hebden, JC and Tziraki, M and Delpy, DT (1997) Evaluation of the temporally extrapolated absorbance method for dual-wavelength imaging through tissuelike scattering media. APPL OPTICS , 36 (16) 3802 - 3810.

Hill, DL and Langsaeter, LA and Poynter-Smith, PN and Emery, CL and Summers, PE and Keevil, SF and Pracy, JP and Walsh, R and Hawkes, DJ and Gleeson, MJ (1997) Feasibility study of magnetic resonance imaging-guided intranasal flexible microendoscopy. COMPUT AIDED SURG , 2 (092-9088 (Print), 5) 264 - 275.

Holder, DS and Mansouri, M (1997) Experimental validation of the accuracy of inversedipole modelling of the EEG in a saline filledspherical tank. MED BIOL ENGIN COMPUT , 35(Sup

I

Inglis, S and Bayford, RH and Holder, DS (1997) The use of low frequency impedance measurement forrecording action potentials from C fibres through the skin. MED BIOL ENGIN COMPUT , 35(Sup

J

Jones, R and Davies-Smith, A and Nuyens, G and Whitlock, T and Peasgood, W and Fry, ME and Bateman, A (1997) The evaluation of people with multiple sclerosis for the use of FES devices. In: (Proceedings) 5th IPEM Clinical Functional Electrical Stimulation Meeting at the Postgraduate Education Centre, Salisbury District Hospital, Salisbury, 13-14 March, 1997. (pp. 10 - 11).

K

Kahugu, E and Joffe, JM and Harris, M and Linney, A and Richards, R (1997) Computer-aided design and manufacture in titanium cranioplasty. In: Journal of Dental Research. (pp. 1043 - 1043).

Kang, C and Paley, M and Ordidge, R and Speller, R (1997) 'In-vivo measurements of T2' in the calcaneus: A comparison with DXA and ultrasound'. In: Journal of Bone and Mineral Research. (pp. 268 - ?).

Kang, C and Paley, M and Ordidge, R and Speller, R (1997) T2' measured in trabecular bone is related to structure independently of density. J BONE MINER RES , 12 T666 - T666.

Kang, C and Paley, M and Ordidge, R and Speller, R and Hornby, S (1997) In-vivo MRI measurements of T2' in the calcaneus: A comparison with DXA and ultrasound. J BONE MINER RES , 12 T646 - T646.

Kang, C and Paley, M and Ordidge, R and Speller, RD (1997) 'T2' measured in trabecular bone is related to structure independently of density. In: (Proceedings) 'T2' measured in trabecular bone is related to structure independently of density. Journal of Bone and Mineral Research.

Kirkby, DR and Delpy, DT (1997) Parallel operation of Monte Carlo simulations on a diverse network of computers. Physics in Medicine and Biology (42 (6)) 1203 - 1208.

Kohl, M and Watson, R and Chow, G and Roberts, I and Delpy, DT (1997) Optical properties of highly scattering media determined from the ratio of changes in attenuation , phase and modulation depth. In: (pp. 307 - 313).

Kohl, M and Watson, R and Chow, G and Roberts, I and Delpy, DT and Cope, M (1997) Monitoring of cerebral haemodynamics during open heart surgery in children using near infrared intensity modulated spectroscopy. PROC S P I E (2979) 408 - 416.

Kwee, IW and Tanikawa, Y and Proskurin, S and Arridge, SR and Delpy, DT and Yamada, Y (1997) Performance of a nullspace-map image reconstruction algorithm. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF , 2979 185 - 196.

L

Lambrou, T and Linney, A and Speller, R (1997) Wavelet Transform Enhancement and Classificatin Applied to Digital Mammography. In: (Proceedings) Conference of the British Institute of Radiology.

Leung, TS and White, PR and Collis, WB and Salmon, AP and Brown, E (1997) Time-frequency methods for analysing paediatric heart murmurs. Appl Sign Process , 4 (3) 154 - 167.

Little, JA and Hawkes, DJ (1997) The registration of multiple medical images acquired from a single subject: why, how, what next? STAT METHODS MED RES , 6 (962-2802 (Print), 3) 239 - 265.

Little, JA and Hill, DLG and Hawkes, DJ (1997) Deformations incorporating rigid structures . Computer Vision Image Understanding , 66 (2) 223 - 232.

Lovell, A and Marshall, A and Owen-Reece, H and Elwell, C and Goldstone, J and Smith, M (1997) Changes in cerebral blood volume with change in posture measured by near infrared spectroscopy. In: J. Neurosurg. Anesthiol. (pp. 405 - ?).

Lovell, A and Owen-Reece, H and Elwell, C and Smith, M and Goldstone, J (1997) Comparison of the immediate effects of induction of anaesthesia with etomidate, propofol and thiopentone on cerebral haemodynamics. In: British Journal of Anaesthesia. (pp. 473P - ?).

Lovell, A and Owen-Reece, H and Elwell, C and Smith, M and Goldstone, J (1997) Oscillations in arterial saturation: implications for the measurement of cerebral blood flow with near infrared spectroscopy. In: Br. J. Anaesth. (pp. 463P - ?).

Lovell, AT and Owen-Reece, H and Elwell, CE and Smith, M and Goldstone, JC (1997) Continuous measurement of cerebral oxygenation by NIRS during induction of anaesthesia. OXYGEN TRANSPORT TO TISSUE XIX , 428 213 - 218.

Lovell, AT and Owen-Reece, H and Elwell, CE and Smith, M and Goldstone, JC (1997) Predicting oscillation in arterial saturation from cardiorespiratory variables - Implications for the measurement of cerebral blood flow with NIRS during anaesthesia. OXYGEN TRANSPORT TO TISSUE XIX , 428 629 - 638.

Luggar, RD and Horrocks, JA and Farquharson, MJ and Speller, RD and Lacey, RJ (1997) Real time analysis of scattered x-ray spectra for sheet explosives detection. Proceedings of SPIE - The International Society for Optical Engineering , 2936 219 - 228.

Luggar, RD and Horrocks, JA and Speller, RD and Lacey, RJ (1997) Low angle X-ray scatter for explosives detection: A geometry optimization. APPL RADIAT ISOTOPES , 48 (2) 215 - 224.

M

Manivannan, A and Hossain, P and Vieira, P and Hipwell, J and Kirkpatrick, N and Lim, C and Sharp, P and Forrester, J (1997) Digital imaging with a scanning laser ophthalmoscope. IEE Colloquium (Digest) (124) 8/1 - 8/6.

Matcher, SJ and Cope, M and Delpy, DT (1997) In vivo measurements of the wavelength dependence of tissue-scattering coefficients between 760 and 900 nm measured with time-resolved spectroscopy. Applied Optics , 36 (1) 386 - 396.

Mehmet, H and Yue, X and Penrice, J and Cady, EB and Wyatt, JS and Sarraf, C and Squier, MV and Edwards, AD (1997) Relation of energy metabolism to apoptosis following cerebral hypoxia-ischaemia (HI). In: Pediatric Research. (pp. 386 - ?).

Miszkiel, KA and Paley, MN and Wilkinson, ID and Hall-Craggs, MA and Ordidge, R and Kendall, BE and Miller, RF and Harrison, MJ (1997) The measurement of R2, R2* and R2' in HIV-infected patients using the prime sequence as a measure of brain iron deposition. Magnetic Resonance Imaging , 15 (10) 1113 - 1119.

Miszkziel, KA and Paley, MNJ and Wilkinson, ID and HallCraggs, MA and Ordidge, R and Kendall, BE and Miller, RF and Harrison, MJG (1997) The measurement of R-2, R-2* and R-2' in HIV-infected patients using the prime sequence as a measure of brain iron deposition. MAGN RESON IMAGING , 15 (10) 1113 - 1119.

Mooney, MJ and Naga, SSD and Speller, RD and Kang, C and Royle, GJ (1997) Corrections for multiple scatter in Compton Scatter Densitometry bone density measurements. In: (Proceedings) 'Corrections for multiple scatter in Compton Scatter Densitometry bone density measurements'. Journal of Bone and Mineral Research.

Mooney, MJ and Speller, RD and Kang, C and Royle, GJ (1997) Compton Scatter Densitometry bone density measurements. Journal of Bone and Mineral Research , 12 (1) 25 - 30.

Mosse, CA and Mills, TN and Bell, DG and Swain, CP (1997) Forces exerted by the endoscopist on the colonoscope during colonoscopy. Gastrointestinal endoscopy , 45 (4) 351 - ?.

Mosse, CA and Mills, TN and Bell, DG and Swain, CP (1997) Forces exerted by the endoscopist on the colonoscope during colonoscopy. GUT , 40 (S1) TH159 - ?.

Mosse, CA and Mills, TN and Bell, DG and Swain, CP (1997) Forces exerted during esophageal dilatation. Gastrointestinal endoscopy , 45 (4) 203 - ?.

Mosse, CA and Mills, TN and Bell, DG and Swain, CP (1997) Forces exerted during oesophageal dilatation. GUT , 40 (S1) TH159 - ?.

Munih, M and Hunt, KJ and Donaldson, N (1997) Unsupported standing in paraplegia with optimal feedback control. In: Rabischong, P and Melin, J and Nalecz, M, (eds.) (Proceedings) Proc. 4th European Conference on Engineering and Medicine, Warsaw, Poland. (pp. 429 - 430).

O

Okada, E and Firbank, M and Delpy, DT (1997) Effect of local and global absorption perturbation in layered media on NIR signal. PROC S P I E (2979) 527 - 532.

Okada, E and Firbank, M and Delpy, DT (1997) Monte Carlo investigation of the effect of skull optical properties on optical pathlength in the brain. PROC S P I E (3194) 28 - 33.

Okada, E and Firbank, M and Schweiger, M and Arridge, SR and Cope, M and Delpy, DT (1997) Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head. Applied Optics (36 (1)) 21 - 31.

Okada, E and Firbank, M and Schweiger, M and Arridge, SR and Cope, M and Delpy, DT (1997) Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head. APPL OPTICS , 36 (1) 21 - 31.

Ordidge, R and Thornton, J and Clemence, M and Punwani, S and Cady, E and Penrice, J and Amess, P and Wyatt, J (1997) NMR studies of hypoxic-ischaemic injury in neonatal brain using imaging and spectroscopy. Adv Exp Med Biol , 428 539 - 544.

Ordidge, R and Thornton, J and Clemence, M and Punwani, S and Cady, E and Penrice, J and Amess, P and Wyatt, J (1997) NMR studies of hypoxic-ischaemic injury in neonatal brain using imaging and spectroscopy. In: Harrison, DK and Delpy, DT, (eds.) Oxygen Transport to Tissue XIX. (539 - 544). Plenum: New York, US.

Ordidge, RJ and Clemence, M and Thornton, JS and Penrice, J and Amess, P and Punwani, S and Tyszczuk, L and Wyatt, JS and Cady, EB and Edwards, AD (1997) Quantitative diffusion and T2 MRI in conjunction with 31P MRS show no regional nor global cerebroprotection effects of intravenous MgSO4 after severe transient hypoxia-ischaemia in the neonatal piglet. In: Proceedings International Society for Magnetic Resonance in Medicine, 5th Annual Meeting. (pp. 1175 - 1175).

Ordidge, RJ and Clemence, M and Thornton, JS and Penrice, J and Amess, PN and Punwani, S and Tyszczuk, L and Wyatt, J and Cady, EB and Edwards, AD (1997) Quantitative diffusion and T2 MRI in conjuncion with 31P MRS show no regional nor global cerebroprotection effects of intravenous MgSO4 after severe transient hypoxia-ischaemia in the neonatal piglet. In: Proceedings of the Annual Meeting of the International Society of Magnetic Resonance in Medicine. (pp. 1175 - ?).

Ordidge, RJ and Punwani, S and Cooper, C and Clemence, M and Amess, PN and Penrice, J and Thornton, JS (1997) Correlation between absolute (dHb) as measured by near infra red spectroscopy (NIRS) and absolute R2* as determined by MRI. In: Proceedings of the Annual Meetingof the International Society of Magnetic Resonance in Medicine. (pp. 600 - ?).

Ordidge, RJ and Thornton, JS and Penrice, J and Cady, EB and Amess, PN and Punwani, S and Clemence, M and Wyatt, JS (1997) Relationship between the cerebral absolute apparent diffusion coefficient (ADC) and phosphorus metabolites during "secondary energy failure" in the newborn piglet. In: Proceedings International Society for Magnetic Resonance in Medicine, 5th Annual Meeting. (pp. 395 - ?).

OwenReece, H and Smith, M and Elwell, CE and Lovell, AT and Goldstone, J (1997) Jugular venous bulb oxygen saturation compared with cerebral saturation measured by near infrared spectroscopy. In: ANESTH ANALG. (pp. S370 - S370). WILLIAMS & WILKINS

P

Peasgood, W and Fry, ME and Whitlock, T and Bateman, A and Jones, R (1997) An inexpensive optical fibre based movement sensor for use in closed loop FES control. In: (Proceedings) 5th IPEM Clinical Functional Electrical Stimulation Meeting at the Postgraduate Education Centre, Salisbury District Hospital, Salisbury, 13-14 March, 1997. (pp. 70 - 71).

Pell, GS and Thornton, JS and Howseman, AM and Gadian, DG and Ordidge, RJ (1997) Optimisation of experimental parameters for diffusion-weighted single-shot trace measurement. In: Proceedings of the Annual Meeting of the International Society for Magnetic Resonance in Medicine. (pp. 1746 - ?).

Penrice, J and Amess, P and Wylezinska, M and Punwani, S and Tyszczuk, L and D'Souza, P and Cady, EB and Edwards, AD and Wyatt, JS and Reynolds, EOR (1997) Magnesium sulphate does not ameliorate the delayed rise in cerebral lactate or fall in N-acetylaspartate following transient hypoxia-ischaemia in the newborn piglet. In: Early Human Development. (pp. 208 - 209).

Penrice, J and Amess, P and Wylezinska, M and Punwani, S and Tyszczuk, L and D'Souza, P and Cady, EB and Edwards, AD and Wyatt, JS and Reynolds, EOR (1997) Magnesium sulphate does not ameliorate the delayed rise in cerebral lactate or fall in N-acetylaspartate following transient hypoxia-ischaemia in the newborn piglet. In: Early Human Development. (pp. 208 - 209).

Penrice, J and Amess, PN and Punwani, S and Wylezinska, M and Tyszczuk, L and DSouza, P and Edwards, AD and Cady, EB and Wyatt, JS and Reynolds, EOR (1997) Magnesium sulfate after transient hypoxia-ischemia fails to prevent delayed cerebral energy failure in the newborn piglet. PEDIATR RES , 41 (3) 443 - 447.

Penrice, J and Lorek, A and Cady, EB and Amess, PN and Wylezinska, M and Cooper, CE and DSouza, P and Brown, GC and Kirkbridge, V and Edwards, AD and Wyatt, JS and Reynolds, EOR (1997) Proton magnetic resonance spectroscopy of the brain during acute hypoxia-ischemia and delayed cerebral energy failure in the newborn piglet. PEDIATR RES , 41 (6) 795 - 802.

Perennes, F and Beard, PC and Mills, TN (1997) Intravascular photoacoustic-photothermal imaging of the arterial wall using an optical fibre probe. In: (Proceedings) Horizons de l'Optique 1997 dixieme colloque de la Societe Francaise d'Optique. (pp. A-13 - ?).

Perkins, TA and Donaldson, N and Harper, VJ and Tromans, AM and Taylor, PN and Wood, DE and Rushton, DN (1997) Post-op time-course of stimulation for the lumbo-sacral root stimulation implant. In: (Proceedings) Proc. 5th IPEM Clinical Functional Electrical Stimulation Meeting, Salisbury.

Punwani, S and Cooper, CE and Clemence, M and Penrice, J and Amess, P and Thornton, J and Ordidge, RJ (1997) Correlation between absolute deoxyhaemoglobin [dHb] measured by near infrared spectroscopy (NIRS) and absolute R2' as determined by magnetic resonance imaging (MRI). OPTICAL IMAGING OF BRAIN FUNCTION AND METABOLISM 2 , 413 129 - 137.

R

Rao, A and Gibson, AP and Holder, DS (1997) EIT images of electrically induced epileptic activity in anaesthetised rabbits. Medical and Biological Engineering and Computing , 35 (1) 327 - ?.

Robinson, M and Fox, N and Speller, RD and Horrocks, JA (1997) Detecting, improving and characterising material in 3-D space.

Roth, SC and Baudin, J and Cady, E and Johal, K and Townsend, JP and Wyatt, JS and Reynolds, EOR and Stewart, AL (1997) Relation of deranged neonatal cerebral oxidative metabolism with neurodevelopmental outcome and head circumference at 4 years. DEV MED CHILD NEUROL , 39 (11) 718 - 725.

Royle, GJ (1997) Computer codes for the BNFL Compton camera project.

Royle, GJ and Speller, RD (1997) Apparatus and methods for detecting and/or imaging gamma radiation. WO 97/.

Royle, GJ and Speller, RD (1997) Compton scatter imaging of a nuclear industry site. In: (Proceedings) IEEE Nuclear Science symposium conference Record, Albuquerque, NM.

Royle, GJ and Speller, RD (1997) The Compton Camera Active Trials: Part 2 - Imaging Cell 3 B212 at the Sellafield plant.

Royle, GJ and Speller, RD (1997) A flexible geometry Compton camera for industrial gamma ray imaging. In: DelGuerra, A, (ed.) 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3. (pp. 821 - 824). I E E E

Rushton, DN and Donaldson, N and Barr, FMD and Harper, VJ and Perkins, TA and Taylor, PN and Tromans, AM (1997) Lumbar root stimulation for restoring leg function: results in papaplegia. Artificial Organs (21) 180 - 182.

Rushton, DN and Donaldson, NDN and Barr, FMD and Harper, VJ and Perkins, TA and Taylor, PN and Tromans, AM (1997) Lumbar root stimulation for restoring leg function: Results in paraplegia. In: ARTIFICIAL ORGANS. (pp. 180 - 182). BLACKWELL SCIENCE INC

Rushton, DN and Perkins, TA and Donaldson, N and Wood, DE and Harper, VJ and Barr, FMD and Holder, DS (1997) LARSI: how to obtain favourable muscle contractions. In: (Proceedings) International FES Society Conference, Vancouver.

Rushton, DN and Perkins, TA and Donaldson, N and Wood, DE and Harper, VJ and Tromas, AM and Barr, FMD and Holder, DS (1997) UNSPECIFIED In: (Proceedings) LARSI: how to obtain favourable muscle contractions.

S

Speller, RD and Malden, C and Ng, E and Horrocks, JA and Luggar, RD and Lacey, RJ (1997) System tuning for x-ray scatter measurements in explosive detection. Proceedings of SPIE - The International Society for Optical Engineering , 2936 191 - 200.

Studholme, C and Hill, DL and Hawkes, DJ (1997) Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. MED PHYS , 24 (094-2405 (Print), 1) 25 - 35.

Summers, PE and Bhalerao, AH and Hawkes, DJ (1997) Multiresolution, model-based segmentation of MR angiograms. J MAGN RESON IMAGING , 7 (053-1807 (Print), 6) 950 - 957.

Swain, CP and Gong, F and Mills, TN (1997) Wireless transmission of a colour television moving image from the stomach using a miniature CCD camera, light source and microwave transmitter. Gastrointestinal endoscopy , 45 (4) 62 - ?.

T

Taylor, P and Fox, J and Todd-Pokropek, A (1997) A model for integrating image processing into decision aids for diagnostic radiology. Artificial Intelligence in Medicine , 9 , Article 3. 10.1016/S0933-3657(96)00368-5.

Taylor, P and Fox, J and ToddPokropek, A (1997) A model for integrating image processing into decision aids for diagnostic radiology. In: ARTIFICIAL INTELLIGENCE IN MEDICINE. (pp. 205 - 225).

Taylor, SJG and Perry, JS and Meswania, JM and Donaldson, N and Walker, PS and Cannon, SR (1997) Telemetry of forces from proximal femoral replacements and relevance to fixation. J BIOMECH , 30 (3) 225 - 234.

Thomas, DL and Pell, GS and Lythgoe, MF and Calamante, F and Sotak, CH and Harris, NG and Busza, AL and Williams, SR and King, MD and Gadian, DG and Ordidge, RJ (1997) NMR studies of misery perfusion in a rat model of middle cerebral artery occlusion. In: Proceedings of the Annual Meeting of the International Society of Magnetic Resonance in Medicine. (pp. 606 - ?).

Thornburn, P and Fader, M and Dean, G and Brooks, R and Cottenden, A (1997) Improving the performance of small incontinence pads: a study of "wet comfort". J Wound Ostomy Continence Nurs , 24 (4) 219 - 225.

Thornton, JS and Mottershead, JP and Yeo, CH and Brenner, RE and McDonald, WI and Miller, DH and Tofts, PS and Barker, GJ and Cady, EB and Ordidge, RJ (1997) High resolution, multi-parameter quantitative MRI studies of rabbit corpus callosum at 7 T. In: MAGMA. (pp. 89 - 89).

Thornton, JS and Ordidge, RJ and Penrice, J and Cady, EB and Amess, PN and Punwani, S and Clemence, M and Wyatt, JS (1997) Anisotropic water diffusion in white and gray matter of the neonatal piglet brain before and after transient hypoxia-ischaemia. MAGN RESON IMAGING , 15 (4) 433 - 440.

Todd-Pokropek, A (1997) How to find the surface when you are drowning in data: boundary conditions and constraints in medical image processing. In: PHYSICA MEDICA. (pp. 197 - 202). GIARDINI EDITORI S A LUGANO

Todd-Pokropek, A and Chameroy, V (1997) Testing data compression for teleradiology including JPEG, LOTs and Wavelets, (Scientific Exhibit). In: Radiology 205 (P). (pp. 626 - 627).

Todd-Pokropek, A and Weatherburn, G and Marsden, P and Young, C and Dicks-Mireaux, C (1997) Dose reduction in CT and with CR plates: the issue of image quality. In: (Proceedings) EuroPACS '97 Processings. (pp. 555 - 560).

W

Weese, J and Penney, GP and Desmedt, P and Buzug, TM and Hill, DL and Hawkes, DJ (1997) Voxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery. IEEE TRANS INF TECHNOL BIOMED , 1 (089-7771 (Print), 4) 284 - 293.

Wells, K and Hebden, JC and Schmidt, FEW and Delpy, DT (1997) The UCL multichannel time-resolved system for optical tomography. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF , 2979 599 - 607.

West, J and Fitzpatrick, JM and Wang, MY and Dawant, BM and Maurer, CR and Jr, K and R M, M and R J, B and C, L and D, C and A, M and F, S and P, V and D, VDE and P A, N and S, S and T S, H and B, H and P F, H and D L, H and D J, S and C, M and J B, V and M A, M and G, W and R, P (1997) Comparison and evaluation of retrospective intermodality brain image registration techniques. J COMPUT ASSIST TOMOGR , 21 (363-8715 (Print), 4) 554 - 566.

Whitlock, T and Peasgood, W and Fry, ME and Bateman, A and Jones, R (1997) Self-optimising electrode arrays. In: (Proceedings) Self-optimising electrode arrays. (pp. 76 - 77).

Wong, JC and Studholme, C and Hawkes, DJ and Maisey, MN (1997) Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study. EUR J NUCL MED , 24 (340-6997 (Print), 6) 642 - 650.

Wood, DE and Donaldson, N and Perkins, TA and Worley, ACM (1997) Multi-moment chair system to measure isometric moments in the paraplegic lower limb - improvements to the original design. In: (Proceedings) Proc. 5th IPEM Clinical Functional Electrical Stimulation Meeting, Salisbury.

Wood, DE and Perkins, TA and Harper, VJ and Tromans, AM and Donaldson, N and Barr, FMD and Rushton, DN and Taylor, PN and Swain, ID (1997) Functional results with a lumbosacral anterior root stimulatror implant. In: Functional results with a lumbosacral anterior root stimulatror implant.

Y

Yu, CH and Donaldson, N (1997) Disability and Controllability after Paralysis: a Kinematic Analysis. In: (Proceedings) International FES Society Conference, Vancouver.

Yu, CH and Donaldson, N (1997) New method for paraplegic FES standing - Control by hand reactions of the leg muscle stimulation. In: New method for paraplegic FES standing - Control by hand reactions of the leg muscle stimulation.

Yue, X and Mehmet, H and Penrice, J and Cooper, C and Cady, E and Wyatt, JS and Raynolds, EOR and Edwards, AD and Squier, MV (1997) Apoptosis and necrosis in the newborn piglet brain following transient cerebral hypoxia-ischaemia. NEUROPATH APPL NEURO , 23 (1) 16 - 25.

Z

Zaccanti, G and Hebden, JC and Sassaroli, A and Blumetti, C and Bassani, M and Ismaelli, A (1997) Imaging of scattering inhomogeneities within highly diffusing media. PROC S P I E (3194) 462 - 470.

This list was generated on Thu May 23 07:11:48 2013 BST.